3.3 Power Supply Options 3.3.1 Battery Two nine-volt alkaline batteries (NEDA 1604) are recommended operation. This is a common type of battery that

Seite 3 - DPG 100 iii Rev Feb 2001

3.6 Restoring the Calibrated Zero To restore the zero, first press and hold the [Clear] button, and while holding <Clear>... ...press the [Z

Seite 4 - CHAPTER 2 INTRODUCTION

4.2 Required Pressures In order to re-calibrate the instrument, you must have a precision pressure standard that can produce the zero-scale, half-sca

Seite 5 - DPG 100 2 Rev Feb 2001

Apply the indicated pressure to the instrument. Press [Clear] until "-P-" is displayed, indicating that the reading is being stored. Fina

Seite 6 - 2.4 Front and Side Views

4.5 Calibration Error Messages If unexpected pressures are encountered during the calibration procedure, the instrument will alert the user by flash

Seite 7 - 2.5 Dimensions

Interface: 3 feet of cable with strain relief Update Rate: same as display Minimum Output:: At least -2.5% of full scale Maximum Output:

Seite 8 - 2.7 Accessories

5.3.2 Limit Option Figure 5-3: Wiring code for limit option 5.3.3 0-5 VDC Output Option Figure 5-4: Wiring code for 0-5 VD

Seite 9 - CHAPTER 3 SET UP

5.3.5 4-20 mA Output Option Figure 5-6: Wiring code for 4-20 mA output option 5.4 Explanation Of Limits Limits allow the instrument to signal b

Seite 10 - DPG 100 7 Rev Feb 2001

• Remove the center screw from the rear of the unit and gently remove the electronics from the housing. Apply power via the integral cable and run t

Seite 11 - CHAPTER 4 CALIBRATION

To change a feature with the Setup Menu: Make sure the instrument is turned off. Press the [On/Off] button. While unit is checking the display (

Seite 12 - 4.3 Calibration Procedure

CONTENTS CHAPTER 1 GETTING STARTED...1 1.1 Quick Start Guide

Seite 13 - DPG 100 10 Rev Feb 2001

6.3 Low Limit Setpoint ("L-LO") Menu Item The Low Limit Setpoint ("L-LO”) menu item determines the pressure reading below which Limi

Seite 14 - CHAPTER 5 OUPUT SIGNALS

6.5.5 [Clear] Button Disable Feature This feature disables the ability to clear the high and low data values with the [Clear] button. The ability to

Seite 15 - DPG 100 12 Rev Feb 2001

Table 7: Available Units for "M" Pressure Reference Setting Engineering Unit I Comment ADC for factory use only PSI PSI DUAL inHg {<0

Seite 16 - DPG 100 13 Rev Feb 2001

"HELP 23”: Self-test error. The engineering unit conversion that you selected cannot be rendered on a 4 digit display. For example, consider the

Seite 17 - DPG 100 14 Rev Feb 2001

Figure 8-1: Power adapter specification CHAPTER 9 WARRANTY REPAIR POLICY Limited Warranty On Products Any Cooper Instruments product which, un

Seite 18 - 6.2 Setup Menu Operation

CHAPTER 6 FIELD SELECTABLE FEATURES ...15 6.1 Introduction ...

Seite 19 - DPG 100 16 Rev Feb 2001

CHAPTER 1 GETTING STARTED IMPORTANT! IT IS RECOMMENDED THAT YOU READ THIS DOCUMENT THOROUGHLY BEFORE APPLYING POWER TO THIS UNIT. THIS DOCUMENT CONTA

Seite 20 - DPG 100 17 Rev Feb 2001

2.2.2 Low Battery Indicator On the left side of the display, just above the minus sign, is the low battery indicator (in the shape of an arrow). Whe

Seite 21 - DPG 100 18 Rev Feb 2001

2.4 Front and Side Views Figure 2-1: Front View Figure 2-2: Side View DPG 100 3 Rev Feb 2001

Seite 22 - CHAPTER 7 TROUBLESHOOTING

2.5 Dimensions Figure 2-3: Dimensions DPG 100 4 Rev Feb 2001

Seite 23 - 7.3 Troubleshooting Hints

2.6 Specifications These specifications are subject to change without notice. Enclosure Rating: NEMA 2 (standard), NEMA 4 (optional; not availab

Seite 24 - DPG 100 21 Rev Feb 2001

CHAPTER 3 SET UP 3.1 Installation When installing the instrument into a process connection, make sure all backpressure is relieved from the system.